Type K Thermocouple Amplifier Signal Conditioner Module with 0 to 5 VDC Analog Output

For Use In
Type K Thermocouple Applications
Thermocouple Module
Type K Thermocouple Amplifier Signal Conditioner Module

The TCA-MS-K-1 Thermocouple Amplifier Module functions to convert the low output voltage signal from a Type K thermocouple probe into a linearized 0 to 5 VDC output voltage. This output is ideal for interfacing to dataloggers, aftermarket ECU's, temperature indicators, chart recorders, controllers, or other instrumentation equipment.

Features
  • - 0 to 5 VDC Output
  • - On-Board CJC
  • - Quick Connection via Mini-Thermocouple Plug (included)
  • - Compact Size, only 2.5" x 2.5" x 0.9"
  • - MADE IN THE USA
Specifications
Thermocouple Input: : Type K
Linearized Analog Output: 0 to 5 VDC
Supply Voltage: 10 to 32 VDC
Temperature Measuring Range: +32 to +2282°F (0 to +1250°C)
Output Scale Factor: 2.2 mV / °F (4.0 mV / °C)
Number of Input Channels: 1
Number of Output Channels: 1
Resolution: Infinite
Response Time: > 1 mS
Non-Linearity: < +/- 2% FRO
Output Cable: 3 conductor, 22 AWG, PVC jacket, 6 foot long
Current Draw: < 50 mA
Humidity: 85% Max. RH (non-condensing)
Liquid & Dust Protection: IP51
Weight: 3 oz (85 g)
Ordering Info Table

SKU: TCA-MS-K-1-IND

We can quickly provide application information, pricing and delivery of these products. Our sales engineers are available to answer your temperature sensor application questions and to help find the right product for you.  

Contact us TODAY!

Call 856-727-0250  or e-mail us tempsensors@alliancesensors.com

 

File Downloads
About the Type K Thermocouple Amplifier Signal Conditioner Module – Single Channel

The single-channel Type K thermocouple amplifier module converts the millivolt-level output of a Type K thermocouple into a 0–5 VDC analog signal suitable for direct input to PLC analog input cards, DAQ systems, and microcontroller ADC inputs. The module handles cold-junction compensation internally, correcting for ambient temperature at the terminal strip so the 0–5 V output represents absolute temperature rather than the temperature difference between the measurement junction and the cold junction.

Single-Channel vs. Multi-Channel Modules

The single-channel module is the appropriate choice when only one thermocouple needs to be converted in a given location, or when thermocouples are distributed across a system and centralized multi-channel conversion would require excessively long Type K extension wire runs. Using a single-channel amplifier local to each thermocouple and transmitting the 0–5 V output (or converting to 4–20 mA for longer runs) allows standard copper instrument cable to be used for the majority of the cable run, reducing the cost of Type K alloy extension wire in large systems.

Output Scaling and Calibration

The 0–5 VDC output is typically scaled so that 0 V corresponds to 0°C and 5 V corresponds to the maximum temperature of the application range — for example, 0–1300°C for EGT monitoring, or 0–500°C for CHT applications. This scaling is set at the factory or configurable in the field depending on the module variant. When integrating with a PLC, the engineer needs to verify the scaling and configure the PLC's analog input scaling parameters to match, ensuring that the displayed temperature value matches the actual thermocouple reading.