AllianceSensors.com - H.G. Schaevitz LLC Click here for Home Page       

    

Products By Application

  • Aerospace / Military
  • Civil Engineering
  • Energy and Power Generation
  • Factory Automation
  • Hydraulics / Pneumatics
  • Industrial OEM
  • Subsea / Marine Hydraulics
  • Mobile Hydraulics

Products By Type

  • Gauging Probes
    • Digital Gauging Probes
    • Analog Gauging Probes
  • Linear Position Sensors
    • LVIT Position Sensors
      • Hydraulic Cylinder Linear Position Sensor
      • Magnetostrictive Replacements Sensors
    • LVDT
      • LVDT - Power Generation
      • LVDT - Heavy Duty
  • LVDT Signal Conditioning
  • Rotary Sensors

Technical Information

  • Application Notes
    • Linear Position Sensor
    • LVDT Position Sensor
    • LVDT Signal Conditioning
    • Rotary Position Sensor
    • Position Sensor Technology Comparison
  • Datasheets
  • Manuals
    • Product Manuals
  • FAQ
    • Linear Position Sensor FAQ
    • LVDT Position Sensor FAQ
    • LVDT Signal Conditioning FAQ
    • Rotary Position Sensor FAQ
    • Position Sensor Technology Comparison
  • Downloads
    • GUI Software for SC-100

Corporate Info

  • Contact Us
  • About Our Company
    • About Our Company
    • Sensor Product Terms and Conditions
    • RMA Evaluation Fees for returns
  • News Articles
    • Industrial Trends
  • Press Releases
  • Site Map
Home » Product by Application » Civil Engineering

LVDT Signal Conditioner DIN Rail Mounted SC-100

LVDT Signal Conditioner

Specifically Designed and Engineered for Automation Measurement Systems and General Industrial Applications

AC-LVDT Signal Conditioner with 2 Point Calibration

Smart setup with 2 front panel push buttons --- NO POTS
TWO (2) YEAR warranty
Use with 3-, 4-, 5-, or 6-wire LVDTs and inductive half-bridges

The LVDT Signal Conditioner SC-100 DIN rail module from the Alliance Sensors Group ends the usual difficulties that accompany AC-LVDT set up with a built-in null indicator and simple front panel pushbuttons to set zero and full scale. Engineered to work with the widest range of AC-LVDTs and inductive half-bridges, the SC-100 module monitors LVDT operation and indicates most common failures.

The SC-100 offers a choice of four excitation frequencies, eight analog DC outputs, and RS-485digital communications. Call for pricing and availability today 856-727-0250.

Applications:

  • Pencil Probe Gauging Systems 
  • General Industrial LVDT Position Sensors 
  • Redundant Control Systems using LVDT Position Sensors
  • High Speed Low Noise Requirements 

 

Features:
  • Smart setup with 2 front panel push buttons --- NO POTS
  • Built-in null indicator: LEDs and separate DC null voltage output
  • Choice of 2.5, 5, 7.5 or 10 kHz nominal excitation frequencies
  • Use with 3-, 4-, 5-, or 6-wire LVDTs and inductive half-bridges
  • Choice of 6 DC voltage outputs and 2 current loop outputs
  • 40 dB range of FS outputs from LVDT: 50 mV rms to 5 Volts rms
  • Fail-safe master/slave syncing eliminates beat frequencies
  • 15 - 30 Volts DC operation, 80 mA maximum operating current
  • Self-diagnostic for LVDT winding failures or cable disconnection
  • Independent failure warning flag via open collector output
  • Digital communications link via RS-485 multi-drop bus with up to 16 individual module addresses
  • Hot swappable: set-up can be saved/reloaded via RS-485 port
  • TWO (2) YEAR warranty instead of industry standard (1) year
 
 SC-100 Data Sheet

 SC-100 Operating Manual

 Downloadable GUI software for SC-100

 

Specifications
Operating power:
+15 to +30 V DC (+24 V DC nominal), 60 mA max. at 24 V DC;
+15 V DC and -15 V DC for -10 V to +10 V DC bipolar output
 
Excitation voltage:
3.0 Vrms sine wave push-pull drive nominal (factory default)
4.5 Vrms sine wave push-pull drive via on-board jumper shift
1.5 Vrms single ended drive for low impedance (100 -150 O) primary
 
Excitation frequencies:
2.5 kHz, 5 kHz, 7.5 kHz, 10 kHz (nominal)
 
Master/slave syncing:
Master output couples up to fifteen slave inputs; if original master fails, new master is automatically generated for fail-safe excitation control.
 
LVDT AC Output Signal:
50 mVrms to 5000 mVrms at LVDT's full scale position
 
Analog DC Outputs:
0 - 5 V, 1 - 5 V, 0.5 - 4.5 V, 0 -10 V, -10 to +10 V, 0.5 - 9.5 V,
0 -20 mA sourcing, 4 -20 mA sourcing
 
Loop resistance:
850 Ω max (current loop output mode, 24 V DC supply)
 
Output non-linearity:
≤0.025% of Full Span Output (FSO)
 
Frequency response:
-3 dB at 10% of excitation frequency (minimum) (standard: DS2-4 off)
-3 dB at 10 Hz (nominal) (low noise setting: DS2-4 on)
 
Noise and ripple:
≤2 mVrms (voltage output), or ≤4 µArms (current loop output.)
 
Fault indication:
Loss of excitation, open primary or secondary, LVDT disconnected
 
Fault output:
LED indicators, open collector output, 50 mA, 26.5 V DC max.
 
Null detection:
Front panel LEDs, ± 30 mV threshold out of ˜ ±1.6V signal level
 
Null output:
LEDs, DC null voltage signal (˜ ±3 V DC = ±FS)
 
Operating Temperature:
-20 °C to +75 °C
 
Temperature coefficient:
-0.002% of FSO / °C (combined zero and span shift)
 
Zero set:
Front panel push button or RS-485 command
 
Full Scale set:
Front panel push button or RS-485 command
 
Digital interface:
RS-485 2-wire multi-drop network, 16 addresses
 
Dimensions

 

 

Authorized
Distributors For:

Marposs Digital and Analog Probes

 

Aerospace / Military Analog Gauging Probes Civil Engineering Digital Gauging Probes Energy and Power Generation Factory Automation Gauging Probes Hydraulic Cylinder Linear Position Sensor Hydraulics / Pneumatics Industrial OEM Linear Position Sensors LVDT LVDT - Heavy Duty LVDT - Power Generation LVDT Signal Conditioning LVIT Position Sensors Magnetostrictive Replacements Sensors Mobile Hydraulics Subsea / Marine Hydraulics